RING COMPRESSOR RB-30

1. Casing is made of aluminum alloy and have excellent features on mechanic strength , durability , light weight and smooth exterior.
2. Impeller is made of aluminum alloy and have excellent features on mechanic strength , durability , and light weight.
3. RB series ring compressors are designed to comply with the safety requirements of CE / cCSAus and have attained their type approval.
4. Design per customers requirement available.
5. Thermal protector is optional.

 

 

Meet CE Norm 89/336,73/23,EN60204-1,EN50081-2,EN50082-2
Degree of protection IP 54 (IP 55 optional)
Insulation class F class (155 degrees centigrade) CE cCSAus

Voltage range /

 Frequency

A 50Hz 500 V
60Hz 575 V
B 50Hz 200 ~ 240 / 345 ~ 416 V
60Hz 208 ~ 275 / 380 ~ 480 V
2 50Hz 200 ~ 240 / 380 ~ 440 V --
60Hz 200 ~ 240 / 380 ~ 440 V
1 50Hz 1 Phase  100 ~ 120 / 200 ~ 240 V --
60Hz
9 50Hz 1 Phase  104 ~ 127 / 208 ~ 254 V
60Hz
Installation Any aspect (Except vertical mounting).
Specification and Operation Diagram

 

 Blowers with 50 Hz
Model Phase

Voltage

Hz

kW

Rated Current
Amps(*1)

 

Max.
Pressure
mbar(*2)

 

Max.
Airflow
m3/min

 

Noise
Level
dB(A) (*3)

Weight
kg

RB30-5B0 3 200 ~ 240 /
345 ~ 416
50 0.38 1.72~2.41 / 0.94~1.35 +95 1.3 69 13.0
RB30-6B0 0.40 1.64~2.26 / 0.93~1.30 +105 13.0
RB30-590 1 104~127 / 208~254 0.38 3.60~3.70 / 1.78~1.86 +85 13.5
RB30-690 0.40 4.21~5.25 / 2.11~2.61 +100 14.9

 

 Blowers with 60 Hz
Model Phase Voltage

Hz

kW

Rated Current Amps (*1)

Max. Pressure mbar(*2)

Max. Airflow

m3/min

Noise Level
dB(A)
(*3)

Weight

kg

RB30-5B0 3 208 ~ 275 / 380 ~ 480 60 0.42 1.88~2.31 / 1.08~1.36 +130 1.6 68 13.0
RB30-6B0 0.50 1.91~2.28 / 1.10~1.31 +150 13.0
RB30-590 1 104~127 / 208~254 0.42 5.33~4.52 / 2.65~2.27 +110 13.5
RB30-690 0.50 5.80~5.21 / 3.00~2.67 +130 14.9

Remark 1. under condition (*2) , the test value.

Remark 2. Max. pressure for continuous operation permitted.

Remark 3. dB(A) value gets from 4 points & 1 meter distance test.

Remark 4. can not be operated with closed intake & outlet , a suitable pressure-relief valve must be used.



     

 

Vacuum with 50 Hz
Model Phase Voltage

Hz

kW

Rated Current  Amps (*1)

Max. Pressure mbar(*2)

Max. Airflow m3/min

Noise Level
dB(A)
(*3)

Weight kg

RB30-5B0 3 200 ~ 240 /
345 ~ 416
50 0.38 1.72~2.42 / 0.97~1.37 -80 1.3 69 13.0
RB30-6B0 0.40 1.61~2.29 / 0.90~1.29 -100 13.0
RB30-590 1 104~127 / 208~254 0.38 3.43~3.61 / 1.78~1.83 -80 13.5
RB30-690 0.40 5.28~4.70 / 2.72~2.41 -115 14.9

 

Vacuum with 60 Hz
Model
Phase Voltage

Hz

kW

Rated Current Amps (*1)

Max. Pressure mbar(*2)

Max. Airflow m3/min

Noise Level
dB(A)
(*3)

Weight kg

RB30-5B0 3 208 ~ 275 / 380 ~ 480 60 0.42 1.84~2.34 / 1.06~1.35 -105 1.6 68 13.0
RB30-6B0 0.50 1.84~2.24 / 1.04~1.27 -135 13.0
RB30-590 1 104~127 / 208~254 0.42 4.96~4.27 / 2.50~2.16 -100 13.5
RB30-690 0.50 5.28~4.70 / 2.72~2.41 -115 14.9

Remark 1. under condition (*2) , the test value.

Remark 2. Max. pressure for continuous operation permitted.

Remark 3. dB(A) value gets from 4 points & 1 meter distance test.

Remark 4. can not be operated with closed intake & outlet , a suitable pressure-relief valve must be used.


     

 
 
Dimensions

 

RB30-5B、RB30-59、RB30-6B

     

 

RB30-69