RB-40-1 2-Stage

1. Casing is made of aluminum alloy and have excellent features on mechanic strength, durability, light weight and smooth exterior.
2. Impeller is made of aluminum alloy and have excellent features on mechanic strength, durability and light weight.
3. RB series Ring Compressors are designed to comply with the safety requirements of CE / c CSA us and have attained their Type Approval.
4. Design per customers requirement available.
5. Thermal protector is optional.

 

Meet CE Norm  89/336,73/23,EN60204-1,EN50081-2,EN50082-2
Degree of protection  IP 54 (IP 55 optional)
Insulation class  F class (155℃)
Voltage range / Frequency B 50Hz 200 ~ 240 / 345 ~ 416 V
60Hz 208 ~ 275 / 380 ~ 480 V
9 50Hz 1 Phase 104 ~ 127 / 208 ~ 254 V
60Hz
Installation  Any aspect.

 

 Blower 50Hz
Model Phase Voltage Hz Rated
Output
kW
Rated Current A (*1) Max. Pressure mbar(*2) Max.
Airflow
m3/min
Noise Level dB(A) (*3) Weight kg
RB40-1-7B0 3

200 ~ 240△ / 345 ~ 416Y

50 1.6 6.53~7.94△ / 3.8~4.58Y +280 2.4 73 28
RB40-1-8B0 2.2 8.8~12.8△ / 5~7.35Y +410 29
RB40-1-790 1 104 ~ 127 / 208 ~ 254 1.5 19.4~23.3 / 9.8~11.7 +260 24.4

 

 Blower 60Hz
Model Phase Voltage Hz Rated
Output
kW
Rated Current A (*1) Max. Pressure mbar(*2) Max.
Airflow
m3/min
Noise Level dB(A) (*3) Weight kg
RB40-1-7B0 3

208 ~ 275△ / 380 ~ 480Y

60 2.05 8.36~7.8△ / 4.6~4.53Y +310 3.0 76 28
RB40-1-8B0 2.55 10.2~11.5△ / 5.6~6.7Y +420 29
RB40-1-790 1 104 ~ 127 / 208 ~ 254 1.75 21.9~17.8 / 11.1~8.94 +230 24.4

Remark 1. Under condition (*2), the test value.

Remark 2. Max. pressure for continuous operation permitted.

Remark 3. dB(A) value gets from 4 points & 1 meter distance test.

Remark 4. Can not be operated with closed intake & outlet, a suitable pressure-relief valve must be used


     

 

 Vacuum 50Hz
Model Phase Voltage Hz Rated
Output
kW
Rated Current A (*1) Max. Pressure mbar(*2) Max.
Airflow
m3/min
Noise Level dB(A) (*3) Weight kg
RB40-1-7B0 3

200 ~ 240△ / 345 ~ 416Y

50 1.6 6.3~7.8△ / 3.6~4.5Y -280 2.4 73 28
RB40-1-8B0 2.2 7.6~12.5△ / 4.3~7.2Y -320 29
RB40-1-790 1 104 ~ 127 / 208 ~ 254 1.5 19.4~23.3 / 9.8~11.7 -280 24.4

 

 Vacuum 60Hz
Model Phase Voltage Hz Rated
Output
kW
Rated Current A (*1) Max. Pressure mbar(*2) Max.
Airflow
m3/min
Noise Level dB(A) (*3) Weight kg
RB40-1-7B0 3

208 ~ 275△ / 380 ~ 480Y

60 2.05 8~7.6△ / 4.4~4.5Y -320 3.0 76 28
RB40-1-8B0 2.55 7.6~12.5△ / 4.3~7.2Y -350 29
RB40-1-790 1 104 ~ 127 / 208 ~ 254 1.75 22.8~17.7 / 11.1~9 -250 24.4

Remark 1. Under condition (*2), the test value.

Remark 2. Max. pressure for continuous operation permitted.

Remark 3. dB(A) value gets from 4 points & 1 meter distance test.